How do I calibrate the vacuum sealer?

  1. Open the lid and confirm that the main power switch is in the OFF position.

  2. Simultaneously hold down the UP ARROW and DOWN ARROW keys, turn main power switch ON, release when CAL appears on the display.

  3. Close lid, machine will automatically start within 15 seconds.

  4. As the display increments up, note the three digit number it levels off at.

  5. Depress the S key to set, open lid and turn power switch back to the OFF position.

  6. Repeat procedure - except this time depress the S key when the display reaches 1 digit below the noted number from step 4.

  7. The vacuum sealer is now calibrated to its environment and ready for use.