How do I setup a program?

Open the vacuum sealer lid, turn main switch to ON position, P1 will appear.
Press the S key to open a program and move forward.

  • LED 1: VACUUM %
    a) Set Vacuum Percentage:
    Use the UP & DOWN keys to select the vacuum percentage (at 99.9% machine offers Extra Vacuum Time).
    Press the S key to move forward.
    b) Set Extra Vacuum Time:
    Use the UP & DOWN keys to select your desired value (up to 30 seconds).
    Press the S key to move forward.

  • LED 2: INERT GAS % [Optional]
    Use the UP & DOWN keys to select the percentage of inert gas injection.
    Press the S key to move forward.

  • LED 3: SEALING TIME
    Use the UP & DOWN keys to select the sealing time in seconds.
    Press the S key to lock in the data.

  • LED 4: AIR RETURN
    No programming necessarry.

We recommend to save following 4 most common used programs into your machine:

P1 for Protein  →  VACUUM % = 99.9%  |  EXTRA VACUUM = 0  |  INERT GAS = 0  |  SEALING TIME = 1.5
P2 for Marinades  →  VACUUM % = 97.5%  |  EXTRA VACUUM = 0  |  INERT GAS = 0  |  SEALING TIME = 1.5
P3 for Sauces  →  VACUUM % = 95.0%  |  EXTRA VACUUM = 0  |  INERT GAS = 0  |  SEALING TIME = 1.5
P4 for Infusion  →  VACUUM % = 99.9%  |  EXTRA VACUUM = 30  |  INERT GAS = 0  |  SEALING TIME = 0

 