How is the thermocouple tested?

heater

Thermocouple wires must be connected properly in the connector; Red to Red
Blue to Blue. Reversing the connection will cause the heater to overheat.

How to test the thermocouple.

Select program P05 and set the temperature to 100 degrees and save it.
The temperature LED will light up for about 15 minutes and will dissappear after
the heater has arrived to the set temperature.

2. Change the program to P06 and set the temperature to 50 degrees and save it.
The temperature LED will not light up because the set temperature is lower
the previous set temperature. Heater needs to cool down from 100 degrees to
50 degrees.

3. After 5 minutes change the the program back to P05. The temperature LED will
light up. Heater needs to warm up from 50 degrees back to 100 degrees.

4. If the temperature LED does not perform as described in step 1 to 3, please review 
the wiring and the thermocouple position.

Minipack does not assume any responsibility or liability for the advice given and shall not be liable for any direct, indirect, special, incidental or consequential damages in connection with the use of this information.